Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Laboratory grad distilled water |
Brand | U R Biocoction |
Material | Borosilicate Glass |
Capacity | 1.5Ltr. |
Model | DUDG-AC-15 |
Features | distillation with auto cut off system |
Automation Type | Semi-Automatic |
Electrode Material | MS |
Handle Material | Glass |
Phase | single |
Operating Voltage | 220-240 |
Conductivity | Less than 3 x 10-6 S/cm |
Dist. Water Output Cap.(Approx) | 2.0- 4.0 Ltr/hr |
Distillate Temperature | 25 to 45 degree C |
Minimum Cooling Water | 1- 2 Ltr/Min |
Condition | New |
Country of Origin | Made in India |
Double Glass Distillation - 1.5 Litre |
Product CODE |
DUSG-AC15 |
DUSG-AC 20 |
DUSG-AC 40 |
Dist. Water OutputCap.(Approx.) |
1.5lt/hr |
2.0 lt/hr. |
4.0 lt/hr. |
Electrical Requirements |
220-240 volts, Single phase 1.5kw, Quartz heater |
220-240 volts, Single phase 2.0kw, Quartz heater |
220-240 volts, Single phase 3.5 kw, Quartz heater |
Minimum Cooling Water requirement |
1Lit/Min |
1 Lit / Min |
2 Lit/ Min |
Biological Activity |
Pyrogen Free |
Pyrogen Free |
Pyrogen Free |
Conductivity S/cm |
<3 x 10-6 |
<3 x 10-6 |
<3 x 10-6 |
AUTO CUT-OFF |
In build |
In build |
In build |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Capacity | 1.5 liter |
Body Material | Stainless Steel, mild steel, Polypropylene (PP) |
Type | Water Softener |
Brand | U R Bicoction |
Condition | New |
Installation Service | No |
Country of Origin | Made in India |
Single Glass Distillation - 1.5 Litre |
Product features:
Water Softener works on the Ion Exchange principle, and is used along with Quartz or Glass distillers. The Water Softener (Product CODE: DUWS) prevents the accumulation of sludge (i.e.deposits of Calcium and Magnesium salts that make the water hard) & Iron related hardness will prevent by product CODE : DUFE .Tap water / borewell water is introduced through the inlet and softened water is drawn at the outlet. The softened water is sent into the Boiler of the Distillation Unit. The Unit can be recharged again with a saturated solution of Sodium Chloride. The output is based on 100 ppm input hardness as CaCo3.During regeneration, 10 litres of sodium chloride solution is passed through the Water Softener gradually, for 1 hour.The Feed water to Distilled water plant should be less than 60ppm of TDS. In most cases, the TDS will be around 400ppm. Hence, we recommend you to use the Water Softener after testing TDS in your laboratory
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Capacity | 2Ltr. |
Usage/Application | Laboratory grad distilled water |
Material | Borosilicate Glass |
Type | Distillation Unit |
Design Type | Customised |
Brand/Make | UR Biocoction |
Country of Origin | Made in India |
Triple Glass Distillation - 2 Ltr. |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | U R Biocoction |
Diameter | 3-4 inch |
Usage | Water Filter |
Maximum Operating Pressure | 0.25HP |
Membrane Type | G1 |
Packaging Type | standard |
I Deal In | New Only |
Country of Origin | Made in India |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Type | Water Softener |
Material | Glass |
Brand | U R Bicoction |
Country of Origin | Made in India |
Single Glass Distillation - 4 Litre roduct features: Water Softener works on the Ion Exchange principle, and is used along with Quartz or Glass distillers. The Water Softener (Product CODE: DUWS) prevents the accumulation of sludge (i.e.deposits of Calcium and Magnesium salts that make the water hard) & Iron related hardness will prevent by product CODE : DUFE .Tap water / borewell water is introduced through the inlet and softened water is drawn at the outlet. The softened water is sent into the Boiler of the Distillation Unit. The Unit can be recharged again with a saturated solution of Sodium Chloride. The output is based on 100 ppm input hardness as CaCo3.During regeneration, 10 litres of sodium chloride solution is passed through the Water Softener gradually, for 1 hour.The Feed water to Distilled water plant should be less than 60ppm of TDS. In most cases, the TDS will be around 400ppm. Hence, we recommend you to use the Water Softener after testing TDS in your laboratory |
Additional Information: